Quick Answer
Vacuum glazing is a sealed unit of two glass panes separated by a gap of a few tenths of a millimetre from which the air has been removed. Tiny pillars hold the panes apart and a fused edge seal keeps the vacuum in. Units around 6 to 13 mm thick can match or beat low-e double glazing at centre pane.
Every insulating glass unit is a compromise between thickness and heat loss. Double glazing needs a gas-filled gap of several millimetres to work well, and triple glazing adds a third pane and a second gap. That is fine for a new aluminium curtain wall, but a Georgian sash window built for 3 mm glass has nowhere to put a 24 mm unit.
Vacuum glazing gets around the problem by removing the gas altogether. This article explains how the units are built, what the published U-values actually mean, how they compare with double and triple glazing, and why heritage retrofit is where vacuum glazing makes its strongest case.
How Vacuum Glazing Works
Heat crosses a glazing unit in three ways: conduction through solids and gases, convection as gas circulates in the cavity, and radiation between the panes. Conventional double glazing tackles conduction and convection with a gas-filled gap, and radiation with a low-emissivity coating.

A vacuum removes the gas, so conduction and convection across the gap fall away almost completely. Pilkington's Spacia range brochure notes that in a standard low-e double glazed unit, the conduction and convection component can account for 70 percent of the heat lost, which is why eliminating it matters so much. A low-e coating on one pane still handles radiation, exactly as in ordinary double glazing.
The three critical components
Removing the air creates a structural problem: atmospheric pressure pushes the two panes together with real force. Every vacuum unit solves this with the same three parts.
- The vacuum gap: in Pilkington Spacia, the space between the panes is just 0.2 mm. LandGlass lists a 0.3 mm vacuum cavity for its LandVac units.
- Support pillars: a grid of tiny spacers keeps the gap open. Pilkington uses pillars 0.5 mm in diameter.
- The edge seal: the perimeter must stay airtight for decades. Pilkington describes its edges as welded to achieve a hermetic seal, and units on the market are generally sealed with solder glass, a powdered glass frit with a low melting point that fuses the panes together.
The pillars and the edge seal are also the weak points thermally. Both are solid paths that conduct heat around the vacuum, so centre-pane figures always look better than whole-window performance.
📐 Technical Note
Check how a Ug value was obtained before comparing products. Pilkington's Spacia data gives a Ug of 1.1 W/m²K as a measured value under EN 674, while its double and triple figures for conventional units are calculated under EN 673. Both describe the centre of the glass only. The whole-window U-value (Uw), which includes the frame and edge, is what building regulations assess.
Vacuum Glazing Products: Spacia and LandVac
Two products dominate discussions of vacuum glazing in Europe, and they illustrate how fast the technology has moved.
Pilkington Spacia
Pilkington describes Pilkington Spacia as the world's first commercially available vacuum glazing. It combines an outer pane of low-e glass with an inner pane of clear float, giving an overall thickness of just over 6 mm. The company says it offers the thermal performance of conventional double glazing in one quarter of the thickness and two thirds of the weight, compared with a typical 24 mm thermally efficient double glazed unit.

The range brochure lists several versions. Standard Spacia STIII at 6.2 mm has a Ug of 1.1 W/m²K and visible light transmittance of 78 percent. Spacia Cool, with a solar control low-e coating, reaches 0.9 W/m²K. Super Spacia, at 8.2 mm with 4 mm panes and a wider pillar array, has the lowest Ug of the range at 0.7 W/m²K. Maximum sizes for the standard 6.2 and 8.2 mm units are 1500 by 2400 mm.
Beyond heat loss, Pilkington lists better acoustic performance than single glazing and reduced internal condensation compared with single glazing, both relevant in older homes. A laminated version, Spacia Shizuka, adds a pane to the outer face for safety and sound reduction, with a Ug of 1.2 W/m²K at 9.2 mm. The company also notes that the product has been used in Japan for more than a decade and installed in the UK and the Netherlands.
LandVac
LandVac is made by the Chinese manufacturer LandGlass, which was founded in 1999 and also builds glass tempering furnaces. Its UK distributor quotes a centre-pane U-value of 0.4 W/m²K for LandVac, built from two panes of 4 mm toughened glass. The LandVac Protect listing on NBS Source, verified by the manufacturer, describes a 13.1 mm laminated security version with a 0.3 mm vacuum cavity, a centre-pane U-value of 0.4 W/m²K, 40 dB acoustic reduction and P1A security classification.
The distributor also points out that LandVac units contain no noble gases, which are energy intensive to produce, and describes the units as fully recyclable. That matters for embodied carbon, a theme that Historic Scotland research on slim glazing also raised, as covered below.
Vacuum Glazing vs Double and Triple Glazing
The fairest comparison uses figures from a single manufacturer and the same basis. Pilkington's Optitherm S1 Plus low-e glass achieves a Ug of 1.0 W/m²K in a double glazed unit, calculated under EN 673, and as low as 0.5 W/m²K in a triple glazed unit. The table puts those figures beside the vacuum products.

Centre-pane performance compared
| Glazing | Overall thickness | Centre-pane Ug (W/m²K) | Source |
|---|---|---|---|
| Single clear glass | One pane | 5.7 | Pilkington Spacia brochure |
| Low-e double glazing, argon | Typically 24 mm | 1.0 | Pilkington Optitherm S1 Plus |
| Low-e triple glazing | Thicker than double | As low as 0.5 | Pilkington Optitherm S1 Plus |
| Pilkington Spacia STIII | 6.2 mm | 1.1 | Pilkington Spacia brochure |
| Pilkington Super Spacia | 8.2 mm | 0.7 | Pilkington Spacia brochure |
| LandVac Protect | 13.1 mm | 0.4 | NBS Source listing |
| Spacia STIII + 16 mm argon + low-e pane | About 26 mm | 0.6 | Pilkington Spacia brochure |
Read the table in two directions. Thickness for thickness, vacuum glazing is in a different league: a 6 to 13 mm unit lands between good double and good triple glazing. Value for value, the best triple glazing and the newest vacuum units are close, but triple glazing needs far more depth and weight to get there.
The last row shows a third option. Pilkington lists hybrid units that pair a Spacia vacuum pane with a conventional low-e pane and a gas-filled cavity, reaching 0.6 W/m²K, and describes Spacia as suitable for use as one pane of a triple glazed "super-window".
🔢 Quick Numbers
- 0.2 mm: vacuum gap in Pilkington Spacia, held open by pillars 0.5 mm in diameter (Pilkington)
- 70 percent: share of heat loss in a standard low-e double glazed unit that can come from conduction and convection (Pilkington Spacia brochure)
- 0.4 W/m²K: centre-pane U-value quoted for LandVac Protect at 13.1 mm (NBS Source)
- 35°C: temperature difference across a vacuum unit recommended as a limit by one manufacturer, because of stress in the edge seal (summary in the insulated glazing overview)
Limitations of Vacuum Glazing
Vacuum glazing is not a straight swap for every window. Its weaknesses come directly from the parts that make it work.

Visible pillars
The support pillars form a regular grid across the glass. They are small, but they are there, and the overview of insulated glazing notes that they rule vacuum units out of applications where a completely unobstructed view is expected. Look at a sample at the distance occupants will actually see it before committing.
Edge losses and temperature stress
Because the edge seal is rigid glass, it carries heat around the vacuum and is stressed when one pane is much hotter or colder than the other. The same overview reports that one manufacturer recommends a maximum temperature difference of 35°C across the unit, and that vacuum-glazed windows can underperform their centre-pane figures because of intense heat transfer at the edge. Frame design and edge cover therefore matter more than with conventional units, much as a thermal bridge in a wall can undo good insulation elsewhere.
⚠️ Common Mistake to Avoid
Comparing a vacuum unit's centre-pane Ug with a triple glazed window's whole-window Uw makes the vacuum option look far better than it is. Always compare like with like: centre-pane against centre-pane, or whole window against whole window using the same frame. For compliance calculations, ask the window maker for a Uw for the actual frame, sash and glazing combination.
Size, cost and processing
Units come in fixed thickness options and within published size limits, and like any sealed unit they cannot be cut down after manufacture, so every pane is ordered to measure. Neither Pilkington nor LandGlass publishes public prices for vacuum units; quotations depend on size, specification and quantity, so price should be checked with suppliers project by project.
Technical specifications should be verified by a licensed professional for your specific project. U-values quoted here are manufacturer centre-pane figures, not whole-window values.
Vacuum Glazing in Heritage Retrofit
The thin profile is why vacuum glazing keeps appearing in conservation work. Pilkington says Spacia can be fitted into old frames designed for single glazing, retaining the appearance of historic buildings, and may allow original frames to be reused if they are in reasonable or repairable condition. It also suggests the product for sliding box sashes and secondary glazing, where thin, light glass is valuable.

Independent research supports the thermal case. Historic Scotland Technical Paper 9, written by Gillian Menzies of Heriot-Watt University and published in 2010, measured ten slim-profile double glazing systems and calculated whole-window performance. The window fitted with vacuum double glazing performed best of all. A single-glazed window with secondary glazing came second, ahead of almost all the other slim systems.
The same paper found that slim-profile double glazing performed better in Victorian style "1 over 1" sashes than in Georgian style "6 over 6" windows. It also noted that inert gases account for a significant share of the embodied energy of most double glazing, with xenon particularly high, a point in favour of gas-free vacuum units.
What to check on a heritage project
- Consent: listed building and conservation area rules apply to glass as well as frames, so confirm with the local authority before specifying replacement glazing.
- Rebate depth: measure the existing glazing rebates; a 6.2 mm unit fits very differently from a 13.1 mm one.
- Sash weight: heavier glass changes the balance of a weighted sash, so check the weights and cords.
- Bar pattern: as Technical Paper 9 found, multi-pane sashes gain less from slim double glazing than large single panes do.
For buildings where the original windows are part of the character, our guides to Georgian architecture and adaptive reuse cover the wider decisions about what to keep. For the physics behind the numbers above, see our explainer on R-value versus U-value, and for how coatings reduce radiant loss in any unit, low-e glass versus standard glass.
Final Thoughts
Bottom Line: Vacuum glazing does not replace triple glazing in a deep modern frame, where triple glazing performs as well and costs less effort to detail. Its real strength is thickness: a 6 to 13 mm unit that performs like good double or near-triple glazing makes it the most credible way to upgrade slender historic windows without losing them.
Comments (0)
Back to Architecture and Design Blog