Quick Answer
District heating is a system that makes heat at a central source, such as a combined heat and power plant, waste incinerator, large heat pump or industrial process, and pipes it as hot water to many buildings. Each building takes heat through a substation or heat interface unit instead of running its own boiler.
In Copenhagen, very few buildings have a boiler. Heat arrives through insulated pipes under the street, and the building simply draws what it needs. That arrangement is so normal in Danish and Swedish cities that residents rarely think about it. In much of the UK and North America, by contrast, district heating still sounds like an experiment.
For architects, the difference shows up in plant rooms, risers, flues, roof space and even the choice between radiators and underfloor heating. This article explains how district heating works, how the technology has changed over five generations, where the heat comes from, how buildings connect, what Copenhagen and Stockholm show at city scale, and what all of it means on the drawing board.
How District Heating Works
The overview of district heating describes it as a system for distributing heat generated in a central location through insulated pipes, for space heating and hot water in homes and commercial buildings. A typical network has three parts.
- Heat sources: plants that produce the heat, from cogeneration stations and boilers to heat pumps, geothermal wells and recovered industrial heat.
- Distribution network: pairs of buried, insulated pipes, one carrying hot water out and one bringing cooler water back. Large city systems use primary pipes around 1,000 mm in diameter feeding smaller secondary and tertiary branches.
- Customer connections: a substation in each building, or a heat interface unit in each dwelling, that passes heat to the building's own system and measures what is used.
Water is the usual carrier, although some older systems still use steam. At the customer end, the network is usually separated from the building's heating system by heat exchangers, so the two bodies of water never mix.
Why the return temperature matters
The water coming back is as important as the water going out. The cooler the return, the more heat each litre has delivered, the more customers a given pipe can serve, and the more efficiently plants such as heat pumps and cogeneration units can run. A building that sends water back too warm wastes network capacity. When a project connects, the return temperature its systems can achieve is one of the first numbers worth agreeing with the operator.
The Five Generations of District Heating
Engineers describe district heating in generations, each defined by its carrier, temperature and typical heat sources. The framework comes from a 2014 review by Lund and colleagues on fourth-generation systems, with a fifth generation added since.

First generation: steam
The first systems, introduced in the United States in the 1880s, piped very hot steam through concrete ducts and burned coal. They were inefficient and less safe than later designs. A few survive, in New York and Paris for example, while others have been upgraded.
Second generation: pressurised hot water above 100°C
From the 1930s to the 1970s, networks switched to pressurised hot water, usually above 100°C, in pipes laid inside concrete ducts. Many were tied to combined heat and power plants burning coal and oil. The Soviet-style systems built across Eastern Europe after the Second World War belong to this generation.
Third generation: pre-insulated pipes below 100°C
Developed in the 1970s and still the most common type worldwide, third-generation systems use prefabricated, pre-insulated pipes buried directly in the ground, with temperatures usually below 100°C. Often called Scandinavian district heating technology, they were driven by energy security after the oil crises and used coal, biomass and waste in place of oil.
Fourth generation: low temperature, 70°C and below
Fourth-generation district heating lowers supply temperatures to 70°C or less, cutting losses and opening the network to low-grade sources such as large heat pumps, data centre waste heat, solar thermal fields and seasonal thermal storage. Denmark is already moving in this direction. These systems also act as a buffer for the electricity grid, turning surplus wind power into stored heat.
Fifth generation: ambient networks
Fifth-generation district heating and cooling, sometimes called cold district heating, circulates water near ground temperature, roughly 10 to 25°C. Each building has its own heat pump, extracting heat from the loop in winter and rejecting heat into it when cooling. Buildings that need cooling can effectively feed buildings that need heat. Pipes need little insulation, but the small temperature difference means larger diameters.
The generations compared
| Generation | Period | Carrier and temperature | Typical heat sources |
|---|---|---|---|
| 1G | 1880s to 1930s | Steam, very high temperature | Coal |
| 2G | 1930s to 1970s | Pressurised water above 100°C | Coal and oil, often with CHP |
| 3G | 1970s onward | Water below 100°C | Coal, biomass, waste |
| 4G | In development | Water at 70°C or lower | Heat pumps, waste heat, solar, storage |
| 5G | In development | Water near ambient, about 10 to 25°C | Ambient water and ground, shared building heat pumps |
Where the Heat Comes From
District heating is a delivery system, not a fuel. That flexibility is its main long-term advantage: the source can change without touching the buildings it serves.

Combined heat and power and incineration
Cogeneration plants make electricity and capture the heat that a power-only station would waste. A simple thermal power station runs at roughly 20 to 35 percent efficiency, while one that recovers waste heat can approach 80 percent overall. Waste-to-energy plants feed many Nordic networks; heat recovered from waste incineration made up 20.4 percent of Danish district heat production according to figures cited in the same overview.
Heat pumps and recovered heat
Large heat pumps can lift low-grade heat from sewage, seawater, rivers and data centres to network temperature. Combined with thermal storage, they let a network soak up cheap renewable electricity. Our guide to how a heat pump works explains the cycle at building scale; district systems apply the same principle at megawatt scale.
📌 Did You Know?
Stockholm installed its first district heating heat pump in 1977, drawing on waste heat from IBM computer servers. The city's heat pump capacity has since grown to about 660 MW, using treated sewage water, seawater, district cooling, data centres and even grocery stores as heat sources.
Geothermal and solar
Paris has used geothermal water at 55 to 70°C, drawn from 1 to 2 kilometres below ground, for domestic heating since the 1970s. In Denmark, several towns run central solar heating fields with thermal storage, and in Alberta, Canada, the Drake Landing Solar Community reached a 97 percent annual solar fraction for heating using borehole storage.
District Heating at City Scale: Copenhagen and Stockholm
The two Nordic capitals show what a mature network looks like, and how it changes over time.

Copenhagen
According to the utility HOFOR, district heating covers 98 percent of the heating demand in Copenhagen. The system has been moving away from fossil fuels: HOFOR converted its Amagerværket power station from fossil fuels to biomass, investing DKK 5.2 billion in a new circulating fluidised bed unit, and spent more than DKK 500 million replacing the last section of its steam network with water-based district heating. In generational terms, the city has retired its final first-generation pipes.
Danish networks typically pair transmission lines running at up to 125°C and 25 bar with distribution networks at up to 95°C and 6 to 10 bar. Most major Danish cities have large networks of this kind.
Stockholm
Stockholm Exergi, owned by the City of Stockholm and Ankhiale, says it supplies heat to more than 800,000 Stockholmers through a district heating network about 3,000 kilometres long, fed by heating and cogeneration plants that burn biofuels and non-recyclable waste and recover residual heat. The company also runs district cooling for shops, offices and data centres, which links back to the heat pump story above.
How Buildings Connect to a District Heating Network
The connection is where the network meets the architecture, and where most design decisions sit.

Building substations
Larger buildings usually connect through a single substation in a plant room: heat exchangers, control valves, pumps and a heat meter. Because the heat is made elsewhere, the building needs no boilers, no flue and no fuel supply, and combustion is removed from the site entirely. Direct connection, where network water runs through the building's radiators, is rare, though the Danish city of Odense has used it.
Heat interface units
In apartment buildings, especially in the UK, each dwelling often gets its own heat interface unit, or HIU. As the operator Veolia explains, an HIU looks much like a boiler and is installed in the same way, but contains one or two plate heat exchangers that turn heat from the shared system into instantaneous space heating and hot water for that home. The building's communal pipework then feeds every flat from a central connection.
⚠️ Common Mistake to Avoid
A frequent error in apartment schemes is treating the communal pipework as an afterthought, tucked into whatever corridor ceiling space is left. Those pipes stay warm all year, so long, poorly insulated runs through corridors leak heat into common areas and can cause summer overheating there. Plan short, well insulated distribution routes and dedicated risers from the first layout, not after the flats are fixed.
Metering and regulation
Metering is part of the connection. In the UK, the government's heat network collection lists the Heat Network (Metering and Billing) Regulations 2014 and the Heat Network Technical Assurance Scheme. England is also preparing heat network zoning under powers in the Energy Act 2023, designating areas where networks are expected to be the lowest-cost route to low carbon heat. The national zoning model has been tested in 28 English towns and cities, and the government published its consultation response in January 2026.
What District Heating Means for Building Design
Connecting to a network changes the brief in ways that are easy to miss at concept stage.
Space and servicing
With no boilers on site, there is no flue to route through the building or terminate at roof level. That can free roof space for photovoltaics, terraces or planting. The trade-off is that the incoming pipes need a protected route from the street, coordinated early with the landscape and below-ground drainage.
Design for low temperatures
As networks move toward fourth-generation temperatures, buildings need heating systems that work with cooler water. Large emitters and radiant floor heating deliver comfort at lower flow temperatures than small radiators, and they return cooler water to the network. A well insulated envelope lowers peak demand and makes low-temperature supply easier to accept.

💡 Pro Tip
Ask the network operator for its connection requirements before stage 2, especially the design supply and return temperatures and any limits on return temperature. Those two figures size your emitters, heat exchangers and pipework, and they are far cheaper to design around at concept than to fix after tender.
Density and building type
Networks make most sense where heat demand is dense. Connecting detached houses is expensive per dwelling, while blocks of flats and mixed-use developments spread the cost of each connection across many users. If your project sits near an existing or planned network, the massing and use mix can affect whether connection is viable.
Carbon accounting
A district heating connection does not guarantee low carbon heat; the result depends on the network's fuel mix and how it changes over the building's life. That is why the source matters for net zero building targets, and why networks that are converting to heat pumps and recovered heat, as Copenhagen and Stockholm are, offer a path that individual boilers cannot. Inside the building, district heat still pairs with mechanical ventilation and heat recovery ventilators to keep demand low.
Wrapping Up
District heating turns a city's waste heat, cogeneration output and renewable electricity into a utility that buildings plug into, much like water or power. Its design consequences are practical and specific: a substation instead of a boiler room, risers and HIUs in housing, heating systems sized for cooler water, and a carbon profile that depends on the network rather than the building.
✅ Key Takeaways
- District heating pipes hot water from central sources to many buildings, which connect through substations or heat interface units.
- Networks have moved from steam (1G) to low-temperature water at 70°C or less (4G) and ambient loops with building heat pumps (5G).
- HOFOR reports that district heating covers 98 percent of Copenhagen's heating demand; Stockholm Exergi serves more than 800,000 people.
- Low return temperatures matter as much as supply temperatures, so emitters and controls must be designed for the network.
- In England, heat network zoning under the Energy Act 2023 will designate areas where networks are expected to be the lowest-cost route to low carbon heat.
For architects working on dense housing or mixed-use schemes, the first useful step is to find out whether a network exists or is planned nearby, and what temperatures it runs at, before the plant room ever appears on a plan.