Quick Answer
Phase change materials (PCMs) store heat by melting and release it by solidifying, at a fixed temperature chosen to sit near room comfort. Built into wallboard, plaster or ceiling tiles, they act like thermal mass without the weight. They only help if the room swings through their melting point every day.
Heavy buildings feel calm in summer because thick masonry soaks up daytime heat and gives it back slowly. Lightweight timber and steel frames do not have that buffer, which is one reason they overheat. Phase change materials offer a way to add the buffer back in a layer only millimetres thick.
The idea is decades old, but products have only recently become easy to install, and field data from real buildings is still thin. This article explains the physics of latent heat, the main families of PCM, how they are packaged for buildings, what a recent field study found, and the limits that decide whether they are worth specifying.
How Do Phase Change Materials Store Heat?
Most building materials store heat as sensible heat: warm a concrete slab and its temperature rises. Phase change materials store most of their heat as latent heat, the energy absorbed or released when a substance changes state while its temperature stays almost constant.

Ice is the familiar example. According to the table of specific latent heats, melting 1 kilogram of water ice absorbs about 334 kilojoules, all at 0°C. A building PCM does the same thing at a more useful temperature. As a room warms past the material's melting point, the PCM melts and soaks up heat, holding the surface near that temperature until it has fully melted. When the room cools at night, it solidifies and gives the heat back.
Latent versus sensible storage in numbers
A product sheet shows the difference clearly. Knauf's Comfortboard brochure lists a 12.5 mm PCM plasterboard with a latent heat capacity of 200 kJ/m², a specific heat capacity of 13 kJ/m²K and a phase change temperature of 23°C. Divide one by the other and a single melt stores as much heat as the same board warming by roughly 15 degrees. Indoors, where temperatures move by a few degrees a day, that latent portion is what does the work.
The brochure claims two layers give the same thermal capacity as a 100 mm concrete wall, at a board weight of 11 kg/m². That figure is the manufacturer's own, but it explains why PCMs interest designers of lightweight buildings.
📐 Technical Note
Compare PCM products by three values together: the phase change temperature or range, the latent heat per square metre of installed product (not per kilogram of pure PCM), and the thickness and weight that deliver it. A high kJ/kg figure for the raw material says little if the board only contains a modest fraction of it.
Types of Phase Change Materials
The classification of phase change materials divides them into organic, inorganic and eutectic groups, with composite and microencapsulated PCMs often treated as engineered subclasses. For buildings, three families matter most.
Paraffins and other petroleum-based organics
Paraffin waxes are the classic organic PCM. They melt over a narrow range, show little or no supercooling and stay stable over many cycles. Organic PCMs in the building-relevant range of 0 to 65°C typically store about 150 to 250 kJ per kilogram.

Two weaknesses follow them everywhere. Thermal conductivity is low, around 0.2 W/mK, so heat moves in and out slowly unless fillers or fins are added. More important for buildings, paraffins are flammable, which affects how they can be used in interior linings.
Salt hydrates
Salt hydrates such as sodium sulfate decahydrate and calcium chloride hexahydrate often store 200 to 300 kJ per kilogram, conduct heat better than organics, pack more storage into a given volume and do not burn. Many are inexpensive.
Their drawbacks are supercooling, phase segregation and incongruent melting, which can steadily reduce storage capacity over repeated cycles unless nucleating agents, thickeners or encapsulation control them. Some are also corrosive to metals.
Bio-based PCMs
Organic PCMs can also be made from plant or animal feedstocks, including fatty acids. BioPCM from Phase Change Solutions is one commercial example, described by the company as plant-based and available for set points from minus 75°C to 175°C. A 2024 Minnesota study notes that most bio-based PCMs do not suffer phase segregation, so their melting point should stay stable over their life.
PCM families compared
| Property | Paraffin (organic) | Salt hydrate (inorganic) | Bio-based (organic) |
|---|---|---|---|
| Typical latent heat | About 150 to 250 kJ/kg | Often 200 to 300 kJ/kg | Within the organic range |
| Fire behaviour | Flammable | Non-flammable | Product-specific fire ratings |
| Supercooling | Little or none | Common, needs nucleating agents | Little or none |
| Long-term stability | Good cycling stability | Risk of phase segregation | Most avoid phase segregation |
| Thermal conductivity | Low, around 0.2 W/mK | Higher than organics | Low, like other organics |
Where PCMs Go in a Building
Raw PCM is a wax or a salty liquid, so it has to be packaged before it can line a room. Microencapsulation wraps tiny droplets in shells, commonly melamine-formaldehyde resins, polyurethanes or acrylics and more recently silica, so they can be mixed into plaster, gypsum or coatings. Macroencapsulation puts larger amounts into pouches, tiles or mats. The product form decides where the PCM can sit.

Wallboard and plaster
PCM plasterboard puts the material directly at the room surface, where it meets the air that needs buffering. The Knauf brochure describes its board as cut, fixed and finished like normal plasterboard on timber or metal framing, and manufactured to EN 520. Plasters with microencapsulated PCM follow the same logic as a wet-applied finish.
Ceiling tiles and above-ceiling mats
Retrofits often place PCM above a suspended ceiling, where tiles or blankets can be laid without disturbing finishes. A 2024 report for the Minnesota Department of Commerce notes that such products can sit above suspended ceilings, be attached to acoustic tiles or be fixed within framing, and that a product combining PCM with standard acoustic ceiling tiles was on the market as of January 2024.
Coupling PCMs with other systems
PCMs behave like distributed thermal mass, so they pair naturally with strategies that already depend on mass. Night purge ventilation and other forms of passive cooling can discharge them overnight. In passive solar design, a PCM layer can play the role a masonry Trombe wall plays in heavier buildings. And because a PCM stores heat rather than resisting its flow, it complements insulation rather than replacing it, a distinction covered in our guide to R-value versus U-value.
What Real Buildings Show
Laboratory and simulation studies of PCMs are plentiful. Monitored buildings are rarer, which makes the Minnesota field study worth reading in full.

🏗️ Real-World Example
Two bank buildings (Bloomington and Shakopee, Minnesota, 2022 to 2023): LHB and Slipstream installed Insolcorp's Templok salt hydrate tiles above existing suspended ceilings and monitored energy for a year. The PCM achieved a full freeze and full thaw in the same day on only 13% of study days in Bloomington and 5% in Shakopee, likely because occupants overrode the night setbacks. Results were inconclusive: savings could not be separated cleanly from the effect of the setbacks themselves.
The Minnesota PCM field study is unusually candid. Its authors conclude that PCM in this setting needs well-controlled HVAC to create the temperature swings that drive complete phase changes. They recommend pairing it with significant night setbacks and pre-conditioning the space before people arrive, so the material is fully melted or fully frozen when the working day begins.
The building details matter as much as the product. Both banks were run by thermostats rather than a building automation system, which made it easy for occupants to change setpoints. Their return air paths also differed: in Shakopee, return air was drawn through the ceiling plenum across the PCM tiles, while Bloomington had ducted returns that bypassed them. During cooling seasons, the team worked with the manufacturer on a pre-cooling routine that ran the HVAC for about two hours before occupancy, during the cool early morning, to refreeze the material.
For an architect, those observations translate into design questions. Will air actually move across the PCM, or is it sealed in a dead void? Who controls the setpoints, and can they defeat the strategy with one button? Is there a cool period each day long enough to discharge the stored heat?
Cost results reflected that. Using the actual installed cost of $5.51 per square foot, the 25-year life cycle analysis showed small positive net savings in Bloomington and a loss in Shakopee, where full cycles were rarest. The report lists consistent setbacks, higher energy prices and peak demand charges as factors that improve the case.
🔢 Quick Numbers
- 334 kJ: heat absorbed by melting 1 kg of ice at 0°C (latent heat table)
- 200 kJ/m²: latent heat capacity of Knauf Comfortboard, phase change at 23°C (Knauf brochure)
- $5.51 per square foot: installed cost of PCM tiles in the Minnesota study (Minnesota Department of Commerce, 2024)
- 13% and 5%: share of study days with a complete daily freeze and thaw at the two Minnesota sites (same report)
Limits and Design Considerations
PCMs are not a product you install and forget. Their performance depends on a handful of decisions that are easy to get wrong.
The melting point has to match the room
A PCM that never melts, or never refreezes, is just an expensive lining. In the Minnesota study, the material was treated as solid below 69°F and liquid above 74°F, so the space had to move through that band every day. Choose the phase change temperature to sit inside the daily swing you expect, not at the thermostat setpoint you hope to hold.

The heat has to go somewhere at night
Stored heat must be discharged before the next day. In cooling-dominated use that means night ventilation, a lower night setpoint or a cool slab. In a sealed building with constant setpoints, the PCM sits half melted and does little. The Minnesota team traced its weak results directly to occupants removing setbacks.
Fire, durability and surface contact
Paraffin-based products bring a fire question that gypsum alone does not. Salt hydrate products avoid it; the Minnesota report notes that Templok carries an NFPA Class A fire rating without flame retardants, and that Insolcorp offers a 25-year warranty. Salt hydrates, in turn, raise the durability question of phase segregation, which manufacturers counter with thickeners and nucleating agents.
Surface contact matters too. A PCM hidden behind carpet, furniture or a closed ceiling void exchanges heat poorly with the room. Exposed ceilings and walls with direct sun or good air movement work best, while thermal weak points elsewhere in the envelope, like a thermal bridge, can overwhelm whatever buffering the PCM provides.
Technical specifications and energy figures should be verified by a licensed professional for your specific project and climate.
The Bigger Picture
The case for phase change materials is usually framed as a product question: which board, which tile, how many kilojoules. The Minnesota banks suggest it is really an operations question. A PCM only works when the building is allowed to breathe through a daily temperature cycle, which is exactly what modern controls and impatient occupants tend to prevent. Designers who want thermal mass in a lightweight building may find the harder task is not specifying the PCM, but writing a control strategy and an owner's manual that let it melt and freeze as intended.